Electrician Harlow

Garage and outdoor electrics: what it costs to run power outside

Running power to a garage, shed or garden office typically costs £400–£900 for lighting and a socket or two on a short run, and £600–£2,500 for a fuller installation with its own small board. It is notifiable work under Part P. And the thing that decides which end of that range you land on is not the outbuilding at all — it is what is already in your consumer unit.

What it costs in 2026

Published UK figures, checked September 2026, for a domestic outbuilding supply:

ScopeTypical costWhat it assumes
Light + 1–2 sockets, short run £400–£900 Under ~10 m, spare way with capacity on the house board
Outbuilding with its own small consumer unit £600–£2,500 Longer run, several circuits, sub-board and its own RCD protection
Single outdoor socket off an existing circuit £90–£200 Weatherproof accessory, RCD protection present, wall directly accessible
Garden office / workshop with heating or machine load Quoted individually Load calculation first — this is not a lighting job
The hidden gate: a spare way is not the same as spare capacity. Every quote at the cheap end assumes your existing board can take another circuit. Two things can stop it — no physical spare way, or a board that is full enough, or old enough, that adding a circuit means replacing it. If that happens the outbuilding job silently becomes a consumer unit replacement first, and several hundred pounds appear that were never in the original price. Photograph the inside of your board before you ask for quotes and the question answers itself.

Yes, it is notifiable

Part P of the Building Regulations covers fixed electrical installations in dwellings in England and Wales, and it explicitly reaches outbuildings — detached garages, sheds, greenhouses. A new supply to an outbuilding is a new circuit, and new circuits are notifiable. In practice:

More detail on which jobs fall inside and outside the rules: Part P — what is notifiable.

The burial-depth claim everyone gets slightly wrong

Search this subject and you will be told the cable "must be buried at 500 mm". BS 7671 does not prescribe a depth. Regulation 522.8.10 requires buried cable to be of a construction suitable for the conditions, buried at sufficient depth to avoid damage from reasonably foreseeable disturbance of the ground, and marked by cable covers or marking tape. Depth is a design decision about your ground, not a number copied off a website.

Common domestic practice for steel wire armoured cable across a lawn is around 500 mm below finished ground level, bedded on and covered with fine sand or sifted soil so no sharp stone sits against the sheath, with yellow-and-black warning tape laid above the cable and below the surface. That is a reasonable default for a lawn. It is not sufficient where the ground will be disturbed more aggressively:

RouteWhat "sufficient" means there
Lawn, bordersCommon practice depth, sand bed, warning tape above
Vegetable bed or anywhere dug regularlyDeeper, or a duct — a spade reaches further than you think
Under a driveway or parking areaDuct, and deeper; vehicle loading and future resurfacing both apply
Across a route with other servicesSeparation from gas and water, and a record of where it runs
Clipped to a wall or fence insteadLegitimate for SWA — no digging, but UV, mechanical protection and fixings all matter

Ask for the route to be photographed and measured before it is backfilled. In ten years, when you are putting in a fence post, that photograph is the most valuable part of the job.

What a proper outbuilding supply includes

The extension-lead question, answered honestly. A flex run out to a shed is the most common unsafe garden electrical arrangement in the country, and because there is no fixed wiring involved, nobody ever inspects it. It sits under mowers and spades, through frost and UV, with a connection outdoors that was never designed to be there. If you need power out there occasionally, use an RCD-protected outdoor socket and unplug it. If you need it permanently, it needs a circuit.

Garden office, workshop, hot tub — load first

A light and a phone charger is a lighting-scale job. A garden office with electric heating, a workshop with a table saw, or a hot tub, is a load job, and it has to start with the arithmetic rather than the cable. A hot tub in particular can draw more than the rest of the outbuilding put together and is one of the few domestic additions that genuinely can exhaust the capacity of an older board. If the load calculation says the existing supply cannot carry it, the answer is not a thicker cable to the shed — see consumer unit replacement, and for equipment used out there, PAT testing.

Before you get quotes

  1. Photograph the inside of your consumer unit — spare ways, and how old it is.
  2. Measure the run from the board to the outbuilding, following the route the cable would take, not the straight line.
  3. List the actual load: lights, sockets, heating, machinery, hot tub.
  4. Say what the cable crosses — lawn, driveway, patio, borders.
  5. Confirm the certificate and Part P notification are in the price.
  6. Check the contractor on the Registered Competent Person Electrical register before booking.

If the existing installation is old enough that you are unsure what state the circuits are in, an EICR before the work is cheaper than discovering it halfway through, and a quote for the outbuilding will be firmer for it.

Get quotes for a garage or outbuilding supply

Tell us the run length, what you need to power, and whether your board has a spare way. Those three facts are what separate a £450 quote from a £2,000 one.

What we will not do: we do not sell your details on, we do not add you to a marketing list, and we do not require a phone number. If you would rather not be called, leave the phone out — email is enough.